国产高清视频色拍,久久亚洲精品国产精品777777,日本亚洲中文字无码,无人在线观看视频高清视频

?

?

?

?

High voltage diesel generator sets


Environmental protection and safety upgrade: Emissions meet National VI/EU standards, standard sound insulation and explosion-proof design, comprehensive safety protection

Advantages of high-voltage transmission: Output voltage ≥ 10kV, reducing long-distance transmission losses, can directly drive high-power equipment, and simplify the distribution system

Intelligent and flexible configuration: integrated PLC control module, supports remote monitoring and multi-machine parallel connection, single machine capacity covers 500kVA-50MVA

High efficiency and durability: Adopting technologies such as high-pressure common rail, the combustion efficiency is improved by 15%-20%, and the fuel consumption is low; high-strength components make the overhaul period reach 15,000-20,000 hours


Crew Introduction
Product Parameters
Case Scene
Options

高壓多圖

1. Analysis and comparison of high-pressure diesel generator sets and low-pressure diesel generator sets


Serial Number

Features

Low pressure unit

High pressure unit

1

capacity

Multiple units can be operated in parallel

Multiple units can be operated in parallel, and the machine room can be built in a centralized manner

2

Conveying distance

Short distance power transmission

Can transmit electricity over long distances

3

Loss

In power transmission and distribution, line losses are large

The line loss in power transmission and distribution is small, and there is no problem of transmission heating.

4

Cost

The initial investment of the equipment is small, the maintenance cost is low, and it has great advantages in low capacity and short distance. When used in high capacity and long distance, the cost will be much higher than that of high-pressure units.

The initial investment of the equipment is large, but the maintenance cost is low. It has obvious advantages for large-capacity and long-distance power transmission and distribution, and the supporting investment cost is low.

5

Operation and maintenance

The operation is relatively simple and has low requirements on operators

The operation is relatively complicated and requires high requirements on operators, who must possess the corresponding high-voltage operation certificate to operate it.

6

Configuration

Configuration is relatively simple

The configuration is relatively complex, especially in terms of generators and output distribution cabinets.

7

Safety

High safety performance, mature technology, and low technical threshold

The safety performance is high, the technology is relatively mature, and the technical threshold is high.

8

Development trend

The low-power segment maintains the traditional market, while the high-power segment has the tendency to be replaced by the high-voltage system.

The use of high-pressure systems is the current global trend, and the demand is gradually increasing.


2. Relationship between power, voltage and current

P=1.732×U×I×COSΦ
Take a 2000kW unit as an example, power factor 0.8, frequency 50Hz low voltage (400V)
The current is: I = P / (1.732 × U × COSΦ) = 2000 × 103 / (1.732 × 400 × 0.8) = 3609A
High voltage (10.5KV)
The current is: I = P / (1.732 × U × COSΦ) = 2000 × 103 / (1.732 × 10.5 × 103 × 0.8) = 137A. The high-voltage transmission current is equivalent to 1/26 of the low-voltage transmission current.

3. Application of high voltage diesel generator sets

According to the application characteristics of the above-mentioned high and low voltage diesel generator sets, in applications with large capacity requirements and long power transmission distances, high-voltage diesel generator sets have obvious advantages such as large capacity, long-distance power supply, centralized construction of computer rooms, strong reliability, and simple supporting power distribution systems. They are an inevitable trend in the selection and application of large-capacity units. High-voltage diesel generator sets have been widely used in banks, data centers, metallurgy, civil aviation and other fields.
The main voltage levels of 50Hz high-voltage diesel generator sets are: 6kV, 6.3kV, 6.6kV, 10kV, 10.5kV, 11kV, etc. The power of a single unit is generally above 1000kW, and multiple units are used in parallel.

4. Structural characteristics of high-voltage diesel generator sets

Serial Number

Device name

Instructions for use

Remark

1

Engine

Generally, the power of a single unit is required to be above 1000KW, and engines such as Cummins and MTU can be selected

No difference from low pressure units

2

Dynamo

Short distance power transmission

There is a big difference from the low-voltage generator

3

Connection method

According to different voltage levels, you can choose generators from brands such as STAMFORD and Kangfu

Shock-absorbing pads installed under the base

4

Parallel control system

The double-bearing generator coupling connection is reliable and safer

There is no obvious difference from the low-voltage parallel control system, and differential protection is added

5

High voltage switch cabinet

Generally includes main controller, synchronization device, etc. COMAP main control system, CUMMINS, CAT, MTU parallel control system, differential protection


6

PT cabinet

The general parallel output switch adopts withdrawable electric vacuum circuit breaker, comprehensive protection system, DC operation



案例

Previous page:Already for the first
Previous page:Already for the first

Online Inquiry

Online Message